1. Pure sine wave output;
2. High efficiency toroidal transformer lower loss ;
3. Intelligent LCD integration display;
4. AC charge current 0-20A adjustable; battery capacity configuration more flexible;
5. Three types working modes adjustable:AC first, DC first, energy-saving mode;
6. Frequency adaptive function, adapt to different grid environments;
7. Built-in PWM or MPPT controller optional;
8. Added fault code query function,facilitate user to monitor the operation state in real time;
9. Supports diesel or gasoline generator, adapt any tough electricity situation;
10. RS485 communication port/APP optional.
تخصيص | ||||
Model WD/WD-T | 70112/24 (701) | 10212/24 (102) | 15224/48 (152) | |
القوة المصنفة | 700 واط | 1000 واط | 1500 واط | |
Peak Power(20ms) | 2100 فولت أمبير | 3000 فولت أمبير | 4500 فولت أمبير | |
ابدأ المحرك | 0.5 حصان | 1 حصان | 1.5 حصان | |
قوة البطارية | 12 / 24VDC | 12 / 24VDC | 24 / 48VDC | |
الحجم (L * W * Hmm) | 340x165x283 | |||
حجم التعبئة (L * W * Hmm) | 405x230x340(1pc) / 475x415x350(2pc) | |||
NW (كلغ) | 9.5(1pc) | 10.5(1pc) | 11.5(1pc) | |
غيغاواط (كلغ) | 11(1pc) | 12(1pc) | 13(1pc) | |
طريقة التثبيت | برج | |||
مدخل | نطاق جهد الإدخال DC | 10.5-15VDC(Single battery voltage) | ||
نطاق جهد إدخال التيار المتردد | 73VAC~138VAC(110VAC) / 83VAC~148VAC(120VAC) / 145VAC~275VAC(220VAC) / 155VAC~285VAC(230VAC) / 165VAC~295VAC( 240VAC) | |||
نطاق تردد إدخال التيار المتردد | 45Hz~55Hz(50Hz)/ 55Hz~65Hz(60Hz) | |||
ماكس شحن التيار المتردد | 0A~20A(Depending on the model,The maximum charging power is 1/4 of the rated power) | |||
طريقة شحن التيار المتردد | ثلاث مراحل (تيار ثابت ، جهد ثابت ، شحنة عائمة) | |||
انتاج | | الكفاءة (وضع البطارية) | ≥85% | ||
جهد الإخراج (وضع البطارية) | 110VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2% | |||
تردد الإخراج (وضع البطارية) | 50 هرتز ± 0.5 أو 60 هرتز ± 0.5 | |||
موجة الإخراج (وضع البطارية) | موجة جيبية نقية | |||
الكفاءة (وضع التيار المتردد) | > 99% | |||
جهد الإخراج (وضع التيار المتردد) | 110VAC±10% / 120VAC±10% / 220VAC±10% / 230VAC±10% / 240VAC±10% | |||
تردد الإخراج (وضع التيار المتردد) | اتبع المدخلات | |||
إخراج تشويه الموجي (وضع البطارية) | ≤3% (تحميل خطي) | |||
لا يوجد فقدان للحمل (وضع البطارية) | ≤1% تصنيف القوة | |||
لا خسارة الحمل (وضع التيار المتردد) | ≤2% rated power( charger does not work in AC mode) | |||
No load loss (Energy saving Mode) | ≤10 واط | |||
نوع البطارية (selectable) | بطارية VRLA | Charge Voltage :14.2V; Float Voltage:13.8V(Single battery voltage) | ||
تخصيص البطارية | يمكن تخصيص معلمات الشحن والتفريغ لأنواع مختلفة من البطاريات وفقًا لمتطلبات المستخدم (يمكن ضبط معلمات الشحن والتفريغ لأنواع مختلفة من البطاريات من خلال لوحة التشغيل) | |||
حماية | إنذار انخفاض الجهد البطارية | Factory default: 11V(Single battery voltage) | ||
حماية البطارية من الجهد المنخفض | الإعداد الافتراضي للمصنع: 10.5 فولت (جهد بطارية واحد) | |||
إنذار الجهد الزائد للبطارية | Factory default: 15V(Single battery voltage) | |||
حماية البطارية من الجهد الزائد | افتراضي المصنع: 17 فولت (جهد بطارية واحد) | |||
الجهد استعادة البطارية الجهد الزائد | Factory default: 14.5V(Single battery voltage) | |||
حماية الطاقة الزائدة | الحماية التلقائية (وضع البطارية) ، قاطع الدائرة أو التأمين (وضع التيار المتردد) | |||
العاكس الناتج حماية ماس كهربائى | الحماية التلقائية (وضع البطارية) ، قاطع الدائرة أو التأمين (وضع التيار المتردد) | |||
حماية درجة الحرارة | > 90 درجة مئوية (إخراج إيقاف التشغيل) | |||
إنذار | أ | حالة العمل العادية ، الجرس ليس له صوت إنذار | ||
ب | أصوات الجرس 4 مرات في الثانية عند فشل البطارية ، والجهد غير الطبيعي ، وحماية الزائد | |||
ج | عندما يتم تشغيل الجهاز لأول مرة ، سيطلب الجرس 5 عندما يكون الجهاز طبيعيًا | |||
داخل وحدة التحكم بالطاقة الشمسية (خياري) | وضع الشحن | PWM or MPPT | ||
charging current | 10A~60A | |||
نطاق الجهد المدخلات الكهروضوئية | PWM: 15V-44V(12V system); 30V-44V(24V system); 60V-88V(48V system) MPPT: 15V-120V(12V system); 30V-120V(24V system); 60V-120V(48V system) | |||
أقصى جهد إدخال PV (Voc) (عند أدنى درجة حرارة) | PWM: 50V(12V/24V system); 100V(48V system) / MPPT: 150V(12V/24V/48V system) | |||
الطاقة القصوى لصفيف PV | 12V system: 140W(10A)/280W(20A)/420W(30A)/560W(40A)/700W(50A)/840W(60A); 24V system: 280W(10A)/560W(20A)/840W(30A)/1120W(40A)/1400W(50A)/1680W(60A); 48V system: 560W(10A)/1120W(20A)/1680W(30A)/2240W(40A)/2800W(50A)/3360W(60A) | |||
خسارة الاستعداد | ≤3 واط | |||
كفاءة التحويل القصوى | > 95% | |||
نمط العمل | البطارية أولاً / التيار المتردد أولاً / وضع توفير الطاقة | |||
وقت النقل | ≤4 مللي ثانية | |||
عرض | شاشة LCD | |||
الطريقة الحرارية | مروحة تبريد في تحكم ذكي | |||
الاتصال (اختياري) | RS485 / APP (مراقبة WIFI أو مراقبة GPRS) | |||
WD series power is from 700w~40kw If you want to get more information, Please contact us |
1. Battery number and capacity should be configured according to the rated voltage of the solar power system or inverter;
2. We offer 3 optional working modes:
01 Grid priority mode: When the grid and battery are connected to the inverter, grid will supply power to the loads directly after voltage being stabilized and charge batteries via inverter. When the grid is cut off, the battery will automatically continue to supply power via inverter.
02 Energy saving mode: If the power of the connected AC loads is lower than 5% of the inverter’s rated power, there will be no output from the inverter. Only the chip of inverter is working. The power consumption of the inverter is only 1~6W. The LCD shows the output voltage 0. If the power of the connected loads is over 5%, within 5S the inverter will automatically convert DC to AC to supply power for the loads . The LCD shows the output voltage.
03 Battery priority mode: When the grid and battery are connected to the inverter, battery will supply power to the loads first. When battery capacity is not enough, the grid will continue to supply power automatically.
طَرد
Carton Box for packaging, or Wooden Box advised for Samples to protect in transportations.
Shipping
1. Fedex/ DHL/ TNT/ UPS for samples, door-to-door.
2. By air or by sea for batch goods, for CFL, Air port/ Port receiving.
3. Customers specifying freight forwarders or negotiable shipping methords.
4. Delivery time: 7 days for samples; 10 to 25 days for batch goods.
A: Are your inverters pure sine wave output?
Q: A Yes, All are true pure sine wave.
A: What kind of output you can do?
Q: Normally we produce inverter with 110V 115V 120V 220V 230V 240V, 50/60Hz self-adaption. If you have special requirements, please tell us for engineer consulting.
A: What’ s the difference between low frequency and high frequency inverter?
Q: Low frequency inverter has various protections, strong ability to adapt to the environment. more reliable, with voltage regulation.
A: What’s the difference between pure sine wave inverter and modified sine wave inverter?
Q: Pure sine wave output inverter is just as good as the Public power grid. Even better. Low repaired rate, long lifespan, Without harmonic pollution, enviromental-friendly and appliances protected.
Modified sine wave output has a negative impact on appliances and can’t load inductive load, such as air contition, refrigerator and etc. Certain motor control circuits don’t like the modified wave.
A: What appliances your inverters can load?
Q: Our inverter can be used in household, Office, agricultural appliances and other inductive load such as refrigerator, air conditioner, water pump, etc.
A: Can you print our company logo on inverters, nameplates and packaging?
Q: Yes, we accept OEM orders.
A: How to choose a right inverter?
Q: Tell us your demand, then our sales will recommend a suitable inverter to you.
A: How to solve the technical problem?
Q: 24 hours after-service consultancy just for you and to make your problem to solveeasily.
A: Do I Need A Power Inverter?
Q: Actually, no. This is the only component of a solar energy system that is not absolutely required. However, if you don’t use one, you will not have 220 or 230 volts AC and will have use battery power alone. This might be acceptable in a small RV or cabin, but most people want to use normal AC appliances.
A: What’s The Difference Between 12, 24, And 48 Volt Inverters?
Q: This refers to the input voltage from the battery bank. The main consideration is that at higher voltages the current is less so that you can use smaller wires between your solar panel array and your battery bank. Of course, when you decide on a system voltage, the Solar Panels, Inverter, and Battery Bank all need to use the same voltage.
A: What to do if the product is broken?
Q: If any product is faulty, you can send the picture or video to us, we sill study it and supply the spare parts of PCB board free for after sale service.